Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-WMSM
Brand:tianyi
1.Micro water quality monitor product introduction:
Micro water quality monitor is used for sampling, data logging, analysis and water resource management, and can monitor multiple water quality parameters.In response to the national policy on strengthening environmental protection, maintaining natural ecological balance, and promoting the sustainable development of the national economy, our company has independently developed and produced small outdoor water quality automatic monitoring station FT-WMSM, which is independently developed and produced according to market needs, combines the methods specified in the national standard with advanced computer technology to realize full automation of the measurement process and can be widely used in surface water quality monitoring of rivers, lakes and other surface water.
The factors that cause surface water eutrophication are mainly chemical factors such as N, P, organic matter, HN4- in water bodies.Therefore, monitoring chemical indicators such as total phosphorus, total nitrogen, ammonia nitrogen, chemical oxygen demand, and permanganate index in surface water has become a necessary task.In conjunction with the conventional five parameters (dissolved oxygen, turbidity, conductivity, temperature, and pH) to monitor the reaction water environment indicators simultaneously.
2.Micro water quality monitor monitoring principle:
This outdoor water station adopts the integrated design principle, including water production and distribution system, detection unit (total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and five measurement modules for conventional five parameters), quality control unit, and auxiliary unit (waste liquid collection, lightning protection, air conditioning, etc.).The core unit is the detection unit, total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and chemical analysis methods strictly follow the national standards.The conventional five-parameter indicators (dissolved oxygen, conductivity, turbidity, temperature, pH) are measured using multi-electrode integration.
3.The main specifications and standards of Micro water quality monitor:
According to design documents, equipment, materials, and construction, it must meet the current requirements of the engineering construction standards and specifications of the People's Republic of China, provinces, autonomous regions, municipalities or industries.The technical standards and specifications followed by this project are as follows:
(1) "Technical Specifications for Monitoring Total Water Pollutant Emissions"
(2) "Methods for Monitoring and Analysis of Water and Wastewater" (Fourth Edition)
(3) "Environmental Water Quality Monitoring Quality Assurance Manual"
(4) "Technical Specifications for Surface Water and Sewage Monitoring" (HJ/T91-2002)
(5) "Technical Guidance on Water Quality River Sampling" (HJ/T52-1999)
(6) "Technical Requirements for Automatic Chemical Oxygen Demand Water Quality Analyzer" (HJ/T377-2007)
(7) "Technical Requirements for Automatic Water Quality Analyzer of Permanganate Index" (HJ/T100-2003)
(8) "Technical Requirements for Automatic Ammonia Nitrogen Water Quality Analyzer" (HJ/T101-2003)
(9) "Technical Requirements for Automatic Analyzer of Total Nitrogen Water Quality" (HJ/T 102-2003)
(10) "Technical Requirements for Automatic Analyzer of Total Phosphorus Water Quality" (HJ/T 103-2003)
(11) "Technical Requirements for Automatic pH Water Quality Analyzer" (HJ/T96-2003)
(12) "Technical Requirements for Automatic Conductivity Water Quality Analyzer" (HJ/T97-2003)
(13) "Technical Requirements for Automatic Turbidity Water Quality Analyzer" (HJ/T98-2003)
(14) "Technical Requirements for Automatic Water Quality Analyzer for Dissolved Oxygen (DO)" (HJ/T99-2003)
(15) Relevant standards and specifications of the country and industry
(16) "Environmental Protection Industry Standards of the People's Republic of China" (HJ/T98-2003)
(17) "Building Lightning Protection Design Code"
(18) "Power Supply and Distribution System Design Specifications"
4.Micro water quality monitor product features:
1.Adopt integrated automatic water quality monitoring station, which can measure multiple elements at the same time;
2.Various analytical and detection units, with low detection limits and meet the requirements of online surface water monitoring;
3.The water collection and distribution unit has water sample pretreatment and backflushing functions, with low failure rate and easy maintenance;
4.The UPS uninterruptible power supply can be optionally equipped to ensure that the water station completes the cleaning process when the power is out;
5.It can be equipped with video surveillance equipment, with real-time remote monitoring function, and realizes all-round monitoring;
6.The area of the whole machine covers a small area of ≤2m2;
7.Equipped with waste liquid separation and waste liquid collection unit,
8.Meet the collection of waste liquid for more than two weeks; be equipped with lightning protection units to ensure stable and reliable operation of the system;
9.Intelligent constant temperature system, equipped with cabinet-type heating and cooling air conditioning, to ensure that the water station operates at the specified working temperature.
5.Micro water quality monitor technical parameters:
project | Performance indicators of total phosphorus, ammonia nitrogen, total nitrogen, chemical oxygen demand, permanganate index parameters | ||||
Total phosphorus | Ammonia nitrogen | Total nitrogen | Chemical oxygen demand | Permanganate index | |
Reference standards | GB11893-89 | HJ/536-2009 | HJ 636-2012 | HJ828-2017 | GB11892-89 |
Measurement range | 0.02~2mg/L (scalable) | 0.1~5mg/L (scalable) | 0.1~10mg/L (scalable) | 15~2000mg/L (scalable) | 0.5~20mg/L (scalable) |
Detection limit | ≦0.01mg/L | ≦0.10mg/L | ≦0.1mg/L | ≦15mg/L | ≦0.1mg/L |
drift | ±5% | ±5% | ±5% | ±5% | ≦0.5mg/L |
Precision | ≤5% | ≤5% | ≤5% | ≤5% | ±5% |
Display error | ±5% | ±5% | ±5% | ±5% | ≤5% |
Voltage impact | ±10% | ±5% | ±10% | ±5% | ±5% |
Temperature influence | ±5% | ±5% | ±5% | ±5% | ±5% |
consistency | ≥90% | ≥90% | ≥90% | ≥90% | ±5% |
Sampling cycle | Time interval (any adjustable 20~9999min) and hourly measurement mode | ||||
Calibration cycle | 1~99 days can be adjusted at any time | ||||
Maintenance cycle | Usually once a month, each time for about 60 min |
Micro water quality monitor regular five-parameter technical indicators:
Five-parameter performance indicators | |||||
Measurement method | pH | Dissolved oxygen | Conductivity | Turbidity | temperature |
Glass electrode method | Fluorescence quenching method | Four-wire electrode method | 90 degree scattering light method | Thermal resistance electrode method | |
Reference standards | GB/T6920-86 | GB/T11913-89 | GB/T6908-201 | GB/T13200-91 | GB/T13195-91 |
Measurement range | 0~14 | 0mg/L ~ 20mg/L | 0ms/m~500ms/m | 0NTU~1000NTU | 0~50℃ |
drift | ±0.1pH | ±0.3mg/L | ±1% | ±5% | —— |
Precision | ≤0.1pH | ≤5% | ≤1% | ≤5% | —— |
Display error | ±0.1pH | ≤5% | ±1% | ±5% | —— |
Voltage impact | ±0.1pH | ≤0.3mg/L | ±1% | ±5% | —— |
Temperature compensation accuracy | ±0.1pH | ±0.3mg/L | ±1% | —— | —— |
Water temperature error | —— | —— | —— | —— | ±0.2℃ |
Calibration cycle | Usually twice a month | ||||
Maintenance cycle | Usually once a month, about 30 minutes each time |
Micro water quality monitor whole machine parameters:
The whole machine parameters | |
Control unit | ARM9 embedded industrial control system |
Display unit | 15-inch color touch screen control |
Temperature control system | Equipped with dual-purpose air conditioning |
UPS voltage-regulated power supply (optional) | The UPS uninterruptible power supply can be optionally installed.In the event of sudden power outage, the measurement and cleaning process can be completed. |
Lightning protection unit | Have lightning protection capabilities |
Power requirements | AC 220 V±22 V, 50 Hz±0.5 Hz |
Communication interface | 2-channel RS485, supports 4G wireless transmission |
The power of the whole machine | ≦2500W (including external pump, air conditioner power\maximum power during operation) |
Ambient temperature | (5~40)℃ |
External dimensions | Height 1900mm×width 1480mm×deep 960mm |
Water station weight | 300kg |
6.Micro water quality monitor configuration list
Serial number | Product Name | quantity |
1 | Stainless steel outdoor cabinet (including air conditioning) | 1 set |
2 | Electrical units (PLC, relay, empty switch, switching power supply, lightning protection) | 1 unit |
3 | Display unit (including 15-inch large screen, microcomputer control program) | 1 set |
4 | Water collection unit (pipe, sampling pump, float) | 1 set |
5 | Water distribution unit (electric ball valve, pipe) | 1 set |
6 | Pretreatment unit (flow cell, liquid level sensor, pressure sensor) | 1 set |
7 | Permanganate index | 1 unit |
8 | COD online monitor (optional) | 1 unit |
9 | NH3N online monitor | 1 unit |
10 | TP online monitor | 1 unit |
11 | TN Online Monitor | 1 unit |
12 | Five parameters (oxygen deoxygen, conductivity, turbidity, temperature, pH) | 1 unit |
13 | Digital meter | 1 unit |
14 | Chemical reagents (240 times/month) free | 1 set |
Recommend Several Excellent Water Quality MonitorsI. Portable Multi-parameter Detector (FT-SS07)It covers all parameters and supports the detection of 12 parameters such as water temperature, conductivity, pH, ammonia nitrogen, dissolved oxygen, COD, turbidity, etc. It adopts all-digital elect...
Explosion - proof weather stations are meteorological monitoring devices specifically designed to operate in hazardous environments. With the development of industries such as manufacturing, military, and chemical, the demand for explosion - proof weather stations has been growing steadily. The main...
Laser methane telemeter, leveraging laser technology, is used to detect the concentration of methane gas in the environment and has been widely applied in natural gas stations, the petroleum and petrochemical industry, the metallurgical industry, the power industry and other places.According to diff...
The measurement of wind speed and direction is of great importance in many fields, such as weather forecasting, high - speed railways, wind power generation, industrial and agricultural production, and scientific research.In the traditional meteorological field, the measurement of wind speed and dir...