Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-DN2
Brand:tianyi
1.Functional features of Power Quality Monitoring Equipment
Power Quality Monitoring Equipment is a tool for monitoring power systems and environmental conditions, providing monitoring and analysis of power quality, environmental and process issues.
1.Multi-channel measurement: 4 voltage channels and 4 current channels are measured simultaneously.
2.Electrical parameter measurement: The voltage amplitude, current amplitude, phase, frequency, active power, reactive power, power factor and other numbers can be measured simultaneously;
3.The voltage harmonic and current harmonic content can be measured 2-64 times;
4.The total harmonic distortion rate can be measured;
5.It can measure and short-term flicker (PST), long-term flicker (PLT), and voltage fluctuations;
6.It can measure positive sequence voltage, negative sequence voltage, zero sequence voltage, and voltage imbalance;
7.It can measure positive sequence current, negative sequence current, zero sequence current, current imbalance;
8.Transient parameter measurement function, with voltage surge and drop event recording function, and automatically starts the wave recording function to record the time of the occurrence of the event and the actual waveform of the five cycles before and after;
9.It has oscilloscope function, which can display the voltage and current magnitude and distortion in real time, and can display the voltage and current waveform on the instrument;
10.The hexagonal diagram display function can perform vector analysis of the metering circuit and the protection device circuit, and conduct wrong wiring checks of the metering device; in the three-phase and three-wire wiring mode, 48 wiring methods can be automatically judged; the automatic calculation function of the power supply is convenient for users who have problems with wiring to calculate the power supply.
11.The large clamp meter can be used to measure the ratio and angle difference of low-voltage current transformers;
12.Harmonic content can be displayed in the form of a bar chart, with good visual effect;
13.Built-in large-capacity data memory (storage interval is 1 second-1000 minutes optional) can be continuously stored for 18 months at a time interval of 1 minute;
14.10-inch large-screen color LCD screen display 1280×800;
15.The touch operation of the capacitive screen is similar to that of the operation of tablets and smartphones, making it easy to learn;
16.Support mouse operation and adapt to operators with different habits;
17.When measuring harmonics, you can automatically determine whether the harmonic content exceeds the standard according to the national standard and give a prompt, which is clear at a glance;
18.The national standard query function of harmonic content ratio can query the allowed values of the national standard;
19.It has a frequency measurement range of 42.5Hz-69Hz, and can measure 50 and 60 power systems.
20.Data can be stored in USB flash drive for historical query.
21.It can be equipped with special data analysis and management software to analyze and process the test results, and can grasp the periodic changes of the power quality and load of the measured points, and play an irreplaceable role in understanding the user's power quality and taking corresponding treatment measures;
22.The analysis software can generate professional power quality analysis reports in accordance with the national standard requirements;
23.The instrument is small in size, light in weight and easy to carry;
24.Built-in high-performance lithium-ion battery, which automatically enters power-saving mode, allows the instrument to work continuously for more than 10 hours without an external power supply, making it convenient for on-site testing;
2.Power Quality Monitoring Equipment Technical Indicators
project | parameter | |
Measure the number of channels | Four-channel voltage, four-channel current | |
Measurement range | Voltage | 0-900V |
Current | Small clamp watch: diameter 8mm, 0-5A-25A (standard) Medium clamp watch: diameter 50mm, 10-100-500A (optional) Large clamp watch: diameter 125×50mm, 40-400-2000A (optional) | |
Phase angle | 0.000-359.999° | |
frequency | 42.5-69Hz | |
Resolution | Voltage | 0.001V |
Current | 0.0001A | |
Phase angle | 0.001° | |
power | Reactive 0.01W, reactive 0.01Var | |
frequency | 0.0001Hz | |
Voltage RMS Accuracy | ≤0.1% | |
Current RMS deviation | ≤0.3% | |
Phase angle error | ≤0.1° | |
Power deviation | ≤0.5% | |
Frequency measurement accuracy | ≤0.01Hz | |
Number of harmonic measurements | 2-64 times | |
Voltage harmonic deviation | When the harmonic is greater than 1% nominal value: ≤1% Reading Harmonic is less than 1% nominal value: ≤0.05% nominal voltage value | |
Current harmonic deviation | When the harmonic is greater than 3% nominal value: ≤1% reading + CT accuracy harmonic is less than 3% nominal value: ≤0.05% current range | |
Voltage imbalance accuracy | ≤0.2% | |
Current imbalance accuracy | ≤0.5% | |
Short flicker measurement time | 10 minutes | |
Long flicker measurement time | 2 hours | |
Flash measurement deviation | ≤5% | |
Display | 1280×800, color wide temperature LCD screen | |
Charging power supply | AC220V±15% frequency 45Hz-65Hz | |
Battery working hours | ≥8 hours | |
Power consumption | <4VA | |
insulation | The insulation resistance of the voltage and current input terminals to the casing is ≥100MΩ.The working power input end bears a power frequency of 1.5KV (valid value) between the housing, which took 1 minute to experiment. | |
Ambient temperature | -20℃~50℃ | |
Relative humidity | 0-95% No condensation | |
Appearance size | 280mm×210mm×58mm (Length×Width×Height) | |
weight | 2Kg |
As a crucial component of the power system, transmission lines undertake the important task of efficiently transmitting the electrical energy generated by power plants to various regions. By constructing a vast transmission network, electrical energy can travel over long distances to meet the electr...
The Eleven - element Photovoltaic weather station is a meteorological monitoring device used in the field of distributed photovoltaic power generation, capable of real - time monitoring of multiple meteorological elements:Scheme 1: Wind speed + Wind direction + Average wind speed + Temperature + Hum...
In today's society, with the acceleration of the processes of industrialization and urbanization, air quality issues have received increasing attention from people. There is a wide variety of pollutants in the air. Among them, the "four gases" (carbon monoxide, sulfur dioxide, nitrogen...
In the road structure system, from top to bottom are the surface course (with a thickness of about 15 centimeters), the base course (with a thickness of about 30 centimeters), the cushion course (with a thickness of about 25 centimeters), and the subgrade. The highway subgrade can encounter problems...