Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-YC06
Brand:tianyi
1.Product introduction of Pool and Spa Water Quality Monitoring
Pool and Spa Water Quality Monitoring monitors pool water temperature, pH, residual chlorine, turbidity, dissolved oxygen, ORP to ensure your pool water remains clean and safe to enjoy.YC06 Online Pool and Spa Water Quality Monitoring is an instrument that can monitor water temperature, ph, residual chlorine, turbidity, dissolved oxygen, orp online.It integrates the corresponding sensor and measurement module communication storage, and can quickly and accurately record key parameters in the water body.At the same time, the instrument supports extended water quality multi-parameter sensors, including but not limited to pH, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data and alarm history records, and support the export of historical data.xlsx.The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2.Pool and Spa Water Quality Monitoring Application Fields
Online Pool and Spa Water Quality Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1.Swimming pool water quality monitoring: used to monitor the pool water quality such as water temperature, ph, residual chlorine, turbidity, dissolved oxygen, orp, etc., in order to ensure the health of swimmers.
2.Groundwater monitoring: used to monitor the pH, conductivity, temperature and other parameters of groundwater in order to promptly discover and solve water quality problems.
3.River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take pollution control measures in a timely manner.
4.Ocean monitoring: used to monitor the ocean's water quality, such as salinity, dissolved oxygen, temperature and other parameters, so as to promptly detect and control marine pollution.
5.Sewage treatment: used to monitor the water quality parameters of sewage, such as pH, COD, ammonia nitrogen, etc., in order to control and regulate the sewage treatment process.
6.Industrial production: used to monitor the water quality conditions in the industrial production process, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process process in a timely manner and ensure product quality.
7.Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
8.Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change and other research.
3.Pool and Spa Water Quality Monitoring technical features
1.High reliability: suitable for long-term working in the wild environment, stable measurement and strong anti-interference ability.
2.Flexible and portable: Each probe can be freely combined, replaced independently, and used for plug and play.
3.Scalability: Freely combine multiple sensors.
4.Multiple applications: rapid on-site measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipeline water.
5.Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6.Compact structure: can be installed in smaller sizes.
7.Communication connection: RS485 extended interface, master/slave interface isolation can communicate independently.
4.Technical parameters of Pool and Spa Water Quality Monitoring
Display output | 4.3-inch touch screen with LED strong backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The instrument power consumption is about 12V/1W |
Sound output | buzzer |
Communication protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main materials | ABS+PC material |
Storage temperature | -20 to 70℃ |
Operating temperature | -10 to 50℃ |
Protection level | IP65 |
size | 175mm*140mm*49mm(Length×Width×Height) |
weight | About 0.5KG |
5.Pool and Spa Water Quality Monitoring sensor configuration (optional)
Serial number | name | Measurement range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
2 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ± 0.1PH | ✔ | |
3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ± 6mv | ✔ | |
4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ||
5 | Turbidity | 0~40NTU (low turbidity) | Scattering light method | ± 1% | ✔ | Optional |
0~1000NTU (medium turbidity) | Scattering light method | ± 1% | ||||
0~3000NTU (high turbidity) | Scattering light method | ± 1% | ||||
6 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ± 2% | ✔ | |
7 | Ammonia nitrogen | 0~100mg/l | Ion Selection Electrode Method | ±1mg | ||
8 | Suspension | 0~2000mg/L | Scattering light method | ±5% (depending on sludge homogeneity) | ||
9 | Residual chlorine | 0~5.00 mg/L | Ion Selection Electrode Method | ±5% of reading | ✔ | |
10 | Chloride ions | 0-3500.0mg/L | Ion Selection Electrode Method | ±5% | ||
11 | Total hardness | 0~1000.0mg/L | Ion Selection Electrode Method | ±10% of reading | ||
12 | cod | 0~500mg/ L | UV254 absorption method | ±5% | COD and chlorophyll have automatic cleaners, which can prevent biological adhesion and avoid light window pollution, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
Although traditional mechanical wind speed and direction meters have, to some extent, met basic requirements, they have limitations in terms of accuracy, response speed, and reliability. With the advancement of technology, the 3D Ultrasonic Anemometer based on the time - difference method has been d...
In daily life, whenever we easily press the switch and the lights turn on instantly and the electrical appliances operate smoothly, few people will think deeply that behind this seemingly ordinary power supply, there is actually a huge and complex technological system operating stably. Among the man...
Meteorology and soil moisture are two fundamental elements in agriculture. Meteorology determines the "timing" of agriculture, while soil moisture reflects the "favorable geographical conditions". Together, they form the environmental framework for crop growth.The dynamic changes...
I. Product IntroductionOur company is a professional manufacturer of meteorological sensors. We have been focusing on the research and development, as well as the production of various meteorological sensors, and also provide meteorological environment solutions. The company has a complete productio...