Model:FT-SS02
Brand:tianyi
1.Product introduction of Blue Green Algae Test
Blue Green Algae Test uses fluorescence detection to tell you whether the green material you see in the water is likely to be blue-green algae.Blue Green Algae Test is an electrode-based water quality analysis instrument that uses all-digital electrode detection to detect two parameters of water quality chlorophyll and blue-green algae.The instrument is equipped with a self-developed FTIOT operating system, which has simple operation, stable performance, accurate measurement, wide detection range, and has a built-in high-capacity rechargeable lithium battery, which is convenient for users to conduct water quality inspection at any time in the field and in the laboratory.
2.Blue Green Algae Test host parameters
Charging input voltage | 4.5V-5.5V |
Charging current | <2A |
Screen size | 3.5 inches |
Screen resolution | 480*800☆ |
Screen interface | MIPI DSI☆ |
USB port | 2 (Support external expansion of mouse, keyboard, 4G, etc.)☆ |
Type-C | 1 (Support external expansion of mouse, keyboard, 4G, etc.)☆ |
RS485 | 2 (Support Modbus, json, asc input, etc.) |
External sensor power supply voltage | 12V |
External sensor power supply current | 1A |
operating system | ftiot (based on Linux-5.4)☆ |
CPU | 2*Cotex-A7, 650Mhz☆ |
RAM | 512M DDR3☆ |
Flash | 8G-64G |
OpenGL | ES 2.0☆ |
Wifi | support |
4G | Selection |
button | support |
Capacitive touch screen | support |
Software Architecture | B/S☆ |
Web access | Support ☆ |
MTP mode | Support ☆ |
Multi-terminal login | Support ☆ |
IPV6 | Support ☆ |
Sensor communication method | RS485, TCP, UDP, Http☆ |
Data forwarding method | RS485, TCP, UDP, Http☆ |
Remote SSH | Support ☆ |
Remote debugging | Support ☆ |
3.Blue Green Algae Test sensor parameters and configuration
Serial number | name | Measurement range | principle | Measurement accuracy | Resolution | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | 0.01℃ | ||
2 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH | 0.01 | ||
3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ±6mv | 1mV | ||
4 | Conductivity | 0~5000uS/cm, 0~10000uS/cm | Contact electrode method | ±1.5% | 1uS/cm | ||
5 | TDS | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
6 | salinity | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
7 | Sludge concentration | 0~20.000g/L | Scattering light method | ±5% (depending on sludge homogeneity) | 0.001g/L | ||
8 | Turbidity | 0~40NTU (low turbidity) | Scattering light method | ±1% | 0.1NTU | Optional | |
0~1000NTU (medium turbidity) | Scattering light method | ±1% | |||||
0~3000NTU (high turbidity) | Scattering light method | ±1% | |||||
9 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ±2% | 0.01mg/L | ||
10 | Ammonia nitrogen | 0~100mg/l | Ion Selection Electrode Method | ±1mg | 0.01mg | ||
11 | Suspension | 0~2000mg/L | Scattering light method | ±5% (depending on sludge homogeneity) | 0.1mg/L | ||
12 | Residual chlorine | 0~5.00mg/L | Ion Selection Electrode Method | ±5% of reading | 0.01mg/L | The best accuracy is when the flow rate is 0.42m/s-0.85m/s | |
13 | Chloride ions | 0-3500.0mg/L | Ion Selection Electrode Method | ±5% | 0.1mg/L | ||
14 | Total hardness | 0~1000.0mg/L | Ion Selection Electrode Method | ±10% of reading | 0.1mg/L | ||
15 | cod | 0~500mg/L | UV254 absorption method | ±5% | 0.1mg/L | COD, chlorophyll, and blue-green algae are equipped with automatic cleaners, which can prevent biological adhesion and avoid light window pollution, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 | 0.01ug/L | ✔ | |
17 | Blue-green algae | 0~200.0Kcells/mL | Fluorescence method | R2>0.999 | 0.1Kcells/mL | ✔ |
Negative oxygen ions are hailed as “air vitamins” and are extremely beneficial to human health. As people’s awareness of health and pursuit of tourism quality have improved, scenic areas’ implementation of negative oxygen ion detection projects can not only create a healthy and comfortable touri...
Entering the high - standard farmland demonstration area, 25 newly installed Solar insecticidal lamps are neatly arranged in the fields. These devices consist of silver lamp poles, black solar panels, and green lamp housings. They absorb solar energy and store electricity during the day, and at nigh...
In the agricultural field, the traditional extensive irrigation method relying on experience is likely to cause either water resource waste or insufficient irrigation. With the rise of precision agriculture, different crops have varying requirements for soil temperature and humidity at different gro...
Nowadays, the demand for meteorological monitoring is no longer limited to fixed locations. In scenarios such as field scientific research, emergency rescue and disaster relief, and temporary event venues, people urgently need a means to obtain meteorological data at any time. As a result, the Porta...